CD(9) FreeBSD Kernel Developer's Manual CD(9)
NAME
cd - CDROM driver for the CAM SCSI subsystem
DESCRIPTION
The cd device driver provides a read-only interface for CDROM drives
(SCSI type 5) and WORM drives (SCSI type 4) that support CDROM type
commands. Some drives do not behave as the driver expects. See the
QUIRKS section for information on possible flags.
QUIRKS
Each CD-ROM device can have different interpretations of the SCSI spec.
This can lead to drives requiring special handling in the driver. The
following is a list of quirks that the driver recognizes.
CD_Q_NO_TOUCH This flag tells the driver not to probe the drive at
attach time to see if there is a disk in the drive and
find out what size it is. This flag is currently
unimplemented in the CAM cd driver.
CD_Q_BCD_TRACKS This flag is for broken drives that return the track
numbers in packed BCD instead of straight decimal. If
the drive seems to skip tracks (tracks 10-15 are
skipped) then you have a drive that is in need of this
flag.
CD_Q_NO_CHANGER This flag tells the driver that the device in question
is not a changer. This is only necessary for a CDROM
device with multiple luns that are not a part of a
changer.
CD_Q_CHANGER This flag tells the driver that the given device is a
multi-lun changer. In general, the driver will figure
this out automatically when it sees a LUN greater than
0. Setting this flag only has the effect of telling the
driver to run the initial read capacity command for LUN
0 of the changer through the changer scheduling code.
CD_Q_10_BYTE_ONLY
This flag tells the driver that the given device only
accepts 10 byte MODE SENSE/MODE SELECT commands. In
general these types of quirks should not be added to the
cd(4) driver. The reason is that the driver does
several things to attempt to determine whether the drive
in question needs 10 byte commands. First, it issues a
CAM Path Inquiry command to determine whether the
protocol that the drive speaks typically only allows 10
byte commands. (ATAPI and USB are two prominent
examples of protocols where you generally only want to
send 10 byte commands.) Then, if it gets an ILLEGAL
REQUEST error back from a 6 byte MODE SENSE or MODE
SELECT command, it attempts to send the 10 byte version
of the command instead. The only reason you would need
a quirk is if your drive uses a protocol (e.g., SCSI)
that typically does not have a problem with 6 byte
commands.
FILES
AUTHORS
This manual page was written by John-Mark Gurney <jmg@FreeBSD.org>. It
was updated for CAM and FreeBSD 3.0 by Kenneth Merry <ken@FreeBSD.org>.
FreeBSD 14.0-RELEASE-p11 March 25, 2014 FreeBSD 14.0-RELEASE-p11